Kuvaus
Multi-function 10-55v DC Brush Motor Encoder Governor DC Motor Controller Overload Protection 12v 24v 36v 48v Adjustable Speed
Product features
LCD Liquid crystal with backlight, can measure input voltage, output current
Can set the slow start and stop time
The speed limit and speed limit can be set
Can set undervoltage power off protection with alarm function (backlight flashing)
Overload power protection with alarm function can be set (backlight flashing)
You can choose to run the motor directly after power-on or not automatically start after power-on
Panel touch switch control acceleration and deceleration can also share the encoder speed regulation start and stop
Product parameters
Input voltage: within DC10-55V (the specific voltage is equal to the rated voltage of the motor)
Measurement voltage: DC10-55V
Measurement current: 20A
starting current: 100ma
Current accuracy: 5%
Speed adjustment type: Current adjustment
Slow Start Slow stop: 0-10
seconds Upper limit Lower limit: 0-100%
Acceleration and deceleration :1%, 2%, 5%, 10%, 15%, 20%, 25%
Optional undervoltage protection: 0-55V can be set
Overcurrent protection mode: Mode 1 disables output, Mode 2 maintains settingCurrent
Overcurrent protection: 0-20A can be set
Power-on startup mode: Mode 1 does not start after power-on. Mode 2 Power-on self-start
motor: brush motor
Speed digital display: 0-100 percentage table (not actual motor speed)
Forward rotation Reverse: not supported
Output voltage: Linear speed
regulation mode under load: point + - encoder
Speed range: 0 -- 100%
Control frequency: 15KHZ
Net weight: 92 grams
Wiring type: fence type wiring terminal According to
mounting mode: embedded
Module size: Length * Height * depth 116mm*76mm*30mm
Panel opening: length * width 109mm*70mm
Note: The input voltage must be equal to the rated voltage of the motor (within 10-55V DC).
For example, rated voltage of the motor 12V input governor 12V Rated voltage of the motor 36V Input governor voltage 36V
Input 220V will burn
Key operation Instructions
Long press the MENU key to enter the setting
Short press MENU key to switch voltage and current
Long press the RUN/STOP key to turn off the backlight
When the voltage and current are overloaded, press the start/stop button to start again
9 Functions are described as follows
Function 1- Slow start time setting: 000-100 (0-10 seconds) slow start time adjustable, default 1 second;
Function 2- Slow down time setting: 000-100 (0-10 seconds) slow down time adjustable, default 1 second;
Function 3- speed limit setting: 000-080 (0-80%) adjustable, default 0;
Function 4- speed limit setting: 000-100 (0-100%) adjustable, default 100%;
Function 5- Add or subtract speed value setting: 1, 2, 5, 10, 15, 20, 25 The percentage of the corresponding change of the speed when the add or subtract key is pressed once,
1%, 2%, 5%, 10%, 15%, 20%, 25%, default 1 (1%);
Function 6- Setting of undervoltage protection value: 0-55V adjustable, setting 0V means no undervoltage protection function, continuous 200ms overlimit is regarded as effective;
Function 7- Setting of overcurrent protection value: 0-20A adjustable (starting at 0.5A, increasing at 0.5A), setting of 0A indicates no overcurrent protection function;
Function 8- Overcurrent protection mode setting: Mode 1 directly shut down the output when the current reaches the protection value of 200ms, mode 2 current reaches the protection
Value 200ms maintain the current limit set protection current value, default mode 1;
Function 9- Power-on startup mode: Mode 1 motor does not start after power-on, mode 2 motor starts after power-on, default mode 1;
9 The operations are described as follows
Slow start time setting Long press the MENU key to enter the function 1 Set the key surface press the add and subtract keys to set the time press RUN/STOP to save and exit
000-100 (10 for 1 second and 100 for 10 seconds) The slow start time is adjustable, the default is 1 second
Setting slow STOP time Long press MENU key to enter setting key surface Short press to switch to function 2 key surface press add and subtract key to set time Press RUN/STOP to save and exit
000-100 (10 for 1 second and 100 for 10 seconds) The slow down time is adjustable, the default is 1 second
To set the speed limit, long press the MENU key to enter the setting key surface, short press to switch to the function. 3 Press the add and subtract keys to set the size. Press RUN/STOP to save and exit
000-080 (0-80%) adjustable, default 0
To set the speed limit, long press the MENU key to enter the setting key surface, short press to switch to the function. 4 Press the add and subtract keys to set the size and press RUN/STOP to save and exit
000-100 (0-100%) adjustable, default 100%
Long press the MENU key to enter the setting key surface
-
Fruugo ID:
420643278-886293354
-
EAN:
7504666301653
Tuoteturvallisuustiedot
Katso tätä tuotetta koskevat tuoteturvallisuustiedot alla
Seuraavat tiedot tarjoaa tätä tuotetta myyvä riippumaton kolmas osapuoli.
Tuoteturvallisuustarrat
Turvallisuusvaroitukset:
WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
Ainesosat:
Octinoxate 3.2960%
Valmistajan osanumero:
DS300872
Mallinumero:
DS858112
Sarjanumero:
DS003352
Eränumero:
DS001432