Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

14,95 €
ILMAINEN toimitus

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

  • Merkki: Unbranded
Myynyt:

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

  • Merkki: Unbranded

14,95 €

Varastossa
ILMAINEN toimitus
Myynyt:

14,95 €

Varastossa
ILMAINEN toimitus

Hyväksymme seuraavat maksutavat

Kuvaus

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

Item Type:Relay Module Product Model: YF-11 Input Voltage:DC7-24V Output Power: Can Control DC Power Load within 10A Time Range: 0.01 Second to 999 Minutes, Any Time Adjustable Function: Pulse Trigger Cycle, Timing, Delay, Power Tube, mos Tube, Field Effect Tube, Switch, Relay Switch Application: It is Often Used to Control Motors, LED Light Strips, DC Motors, Micro Water Pumps, Solenoid Valves, Etc. P-21: Give the signal, after a delay of A second, the output starts P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops P-24: There is a signal. After A second, the output starts, and after the signal disappears for more than A second, the output stops. P-25: When there is a signal, the output will start after A second, and the output will stop when there is another signal for more than A second P-26: There is a signal, the output stops after A second, and the signal disappears and the output stops after A second. P-27: Detection of a pulse signal, the output stops no pulse signal, more than A second output start (the signal continues or the signal disappears are regarded as no pulse signal) P-28: After power on, after a delay of A second, the output starts until the power is off P-31: After power on, the output starts for A second, stops for B second, infinite loop power off stops P-32: When there is a signal, start P-31 infinite loop when the signal disappears, terminate the loop P-33: Give a signal to start P-31 infinite loop give another signal to terminate the loop P-34: After power-on, after a delay of A second, the output will start, and it will stop after closing B seconds P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull-in for B seconds P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped. P-37: When there is a signal, the output starts and stops automatically for A second, and then counts for B seconds after it stops. The signal trigger is invalid within AandB time P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops P-41: No action with signal trigger when signal disappears disconnect after output start delay A time P-42: The signal disappears, after a delay of time A, the output starts working time B ends P-43: The signal disappears. After the time A exceeds, the output starts the working time B ends P-44: After power on, the output will start A time, stop B time cycle C times and automatically stop. P-45: No action when energized, after signal is given output starts A time, stops B time cycle C times and automatically stops Give signal again, execute again P-46: After giving the signal more than A times, the output will start keep the output stop when the power is off P-47: After giving the signal more than A times, the output starts and stops for B seconds P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds 3. Description of button setting: Power on display "" means entering standby state Press K1 for the first time, (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjustment main mode, K3K4 adjustment function Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit) Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit) Press K1 for the fourth time, the display "" means entering the standby state Press K4 in standby mode to permanently turn off or on the display and switch to low power consumption mode 4. The decimal point time unit description: X.XX The decimal point is in hundreds, and the timing range: 0.01 seconds to 9.99 seconds XX.X The decimal point is in the tenth place, timing range: 0.1 second to 99.9 seconds XXX has no decimal point, timing range: 1 second to 999 seconds XXX. The decimal point is in the ones place, and the timing range: 1 minute to 999 minutes Note: Due to the light and screen setting difference, the item's color may be slightly different from the pictures. Please allow slight dimension difference due to different manual measurement.
  • Fruugo ID: 434569827-911853955
  • EAN: 9316197747620

Toimitus ja palautukset

Lähetetään 2 päivän kuluessa

  • STANDARD: ILMAINEN - Toimitus välillä ma 15 joulukuuta 2025–ma 22 joulukuuta 2025 - ILMAINEN

Lähetyspaikka: Kiina.

Teemme parhaamme varmistaaksemme, että kaikki tilaamasi tuotteet toimitetaan sinulle toiveidesi mukaisesti. Jos sinulle toimitettu tilaus kuitenkin on puutteellinen tai sisältää tilaamattomia tuotteita, tai jos et jostain muusta syystä ole tyytyväinen tilaukseesi, voit palauttaa tilauksen kokonaan tai osittain. Saat tuotteista täyden hyvityksen. Näytä koko palautuskäytäntö

Tuotteen vaatimustenmukaisuustiedot

Katso tätä tuotetta koskevat yhteensopivuustiedot alla.

Seuraavat tiedot tarjoaa tätä tuotetta myyvä riippumaton kolmas osapuoli.

Valmistaja:
Alla oleva informaatio sisältää Fruugossa myytävän tuotteen valmistajan yhteystiedot.

  • Foshan Panweibai Trading Co., Ltd.
  • Foshan Panweibai Trading Co., Ltd.
  • Room 103, No. 57, Shalong Road, Jiujiang Town, Nanhai District, Foshan City
  • Foshan
  • CN
  • 528203
  • razer0815@outlook.com
  • 13790744267

Vastuuhenkilö EU:ssa:
Alla oleva informaatio sisältää EU:n alueen vastuuhenkilön yhteystiedot. Vastuuhenkilö on EU:n alueella sijaitseva nimetty talouden toimija, joka on vastuussa asianomaisen EU:n alueelle myytävän tuotteen vaatimustenmukaisuudesta.

  • Jean Luc
  • In Memoria Futuri SAS
  • 3 RUE DU PAS DE LA MULE 75004 PARIS
  • Paris
  • France
  • 75004
  • infoapexchen@gmail.com
  • 33745713901